Controlled from tender to handover.
A defined delivery lifecycle, daily site reporting, a live company dashboard and an integrated quality, health, safety and environmental management system certified to three ISO standards.
Six stages, every project.
Every project is baselined from its tender: the estimate, programme and procurement plan become the project's controls.
Tender
- Scope review against drawings and specifications
- Quantity take-off and priced estimate
- Tender programme and manpower histogram
- Value-engineering options
Engineering
- Shop and coordination drawings
- Load, head and ESP calculations
- Material submittals and samples
- Authority design approvals
Procurement
- Approved makes and vendor list
- Long-lead equipment ordered first
- No order without approved submittal
- Delivery tracked to programme
Construction
- Own trades plus specialist subcontractors
- Area-by-area work sequence
- WIR and MIR inspection regime
- Daily site and manpower reports
Commissioning
- Pressure and insulation tests before concealment
- System commissioning and balancing
- Integrated systems testing
- Authority inspections
Handover
- As-built drawings
- O&M manuals and spare parts
- Client staff training
- Defects liability support
Every project on one page.
Cost, progress, manpower and cash are reported from site data, not estimates. Clients and consultants receive a monthly progress report with the submittal, RFI and inspection logs.
Company dashboard
Every live project on one portfolio view: programme, progress, submittals, inspections, safety and a status rating, refreshed from the project registers.
Daily manpower return
A standard end-of-day report from every site: trades, headcount and area of work, split into in-house manpower and subcontractors.
Histograms and productivity
Actual manpower histograms for the company and each project, compared with the tender histogram to measure productivity and plan resources.
Procurement tracking
Every long-lead item tracked from approved submittal to order, factory test and delivery against the required-on-site date.
Monthly project audit
A review, independent of the project team, of each project's contract, programme, cost, billing and document control, with findings tracked to close-out.
Look-ahead planning
Rolling three-week look-ahead programmes agreed with the main contractor, linking area handovers, inspections and deliveries.
We hold ourselves accountable for quality, health, safety and the environment – to our clients, our people and the communities we build in.
Quality
- Inspection and test plan for every system
- Material inspection on delivery (MIR)
- Work inspection before concealment (WIR)
- Tests witnessed by the consultant
- Non-conformance and corrective action records
Health & safety
- Site induction and daily toolbox talks
- Permit to work for hot work, energised systems and work at height
- PPE and HSE rules applied on every site
- Incident reporting and investigation
Environment
- Waste segregation and removal from site
- Spill control for oils, refrigerants and chemicals
- Energy-efficient equipment (Green Building regulations)
- Refrigerant recovery during replacement works
- ISO 14001 objectives and targets
Authorities we design, install and test to
Every system proven before handover.
Tested before concealment, commissioned with the manufacturers, balanced to design flows, inspected by the authorities and handed over with complete records.

| Stage | Activities |
|---|---|
| Commissioning plan | Issued at 60% progress: systems, sequence, specialists, power and water availability, witnessing and authority inspections. |
| Tests before concealment | Duct leakage; hydrostatic tests on CHW, water and fire piping; drainage tests; refrigerant pressure and vacuum; insulation resistance; earth resistance. |
| Pre-commissioning | Cleaning, flushing and chemical treatment of CHW; equipment checks; protection settings; energisation after authority connection. |
| Commissioning and balancing | Start-up of chillers, AHUs, pumps, VRF, generators, fire pumps and BMS with the manufacturers; air and water balancing to design flows. |
| Authority inspections | DEWA, SEWA, ADDC, Etihad WE, Civil Defence, district-cooling provider, telecom and municipality inspections and completion certificates. |
| Integrated systems testing | Fire alarm interfaces with smoke control, HVAC shutdown, lifts, access control and BMS, tested with the main contractor. |
No single point of failure.
At least two approved sources for every critical category, UAE factories preferred for shorter lead times and in-country value, and long-lead equipment ordered first and tracked weekly.
| Category | Manufacturers and key suppliers used on company projects |
|---|---|
| HVAC equipment | Daikin, Carrier, LG Multi V, VTS air handling, Leminar, SKM; ETS by District Cooling International |
| Ductwork, dampers and insulation | Explorer Duct factory, Delta Duct, Techno Pro, Betec dampers, Hira Industries, Astic and Beta Industrial insulation |
| LV switchgear and busbar | Al Jalal, Al Qudrah, Evershine, Glitter and Power Energy switchgear; Al Ittihad; Al Sanaya busway |
| Cables and wiring devices | NCI, Riyadh Cables, Elsewedy, Ducab and Oman Cables |
| Pumps, plumbing and drainage | Grundfos, Wilo, Polyfab, Gulf Plastic, SEAQ GRP tanks |
| Fire, BMS, ELV and power | NAFFCO fire and smoke systems; Honeywell BMS; Wotek BMS; Scientechnic; Epsilon WAV (ELV); Genyard and Casablanca generators |
Documented, measured, improved.
An integrated management system manual, four policies, fifteen operating procedures and project templates, applied through each project's Project Quality Plan and Project HSE Plan.
Primavera programmes
Level 4–5 programmes with resource loading and three-week look-aheads.
MEP models
LOD 300–400 models and clash-checked coordination drawings.
AutoCAD MEP & Revit
Shop drawings in AutoCAD MEP and Revit.
Company dashboard
Cost, progress, manpower and procurement refreshed daily from site registers.

Tendering an MEP or EPC package?
Send us your tender documents, drawings and BOQs. Our pre-construction team returns a priced offer with a tender programme and technical submission.